Re: Log-Shipping Standby Server: USE_FLOAT8_BYVAL compatibility error

Поиск
Список
Период
Сортировка
От Mathias Breuninger
Тема Re: Log-Shipping Standby Server: USE_FLOAT8_BYVAL compatibility error
Дата
Msg-id 004701cd8b47$d6a4b5f0$83ee21d0$@breuninger@espace29.asso.fr
обсуждение исходный текст
Ответ на Re: Log-Shipping Standby Server: USE_FLOAT8_BYVAL compatibility error  (Craig Ringer <ringerc@ringerc.id.au>)
Список pgsql-admin
On 09/04/2012 11:45 PM CEST, Craig Ringer wrote:
> > The 64 bits server is the master and I tried to configure the 32 bits
> one as a standby server.
>
> That isn't a supported configuration. The standby needs to be the same
> architecture as the master and needs to use the same compilation
> options.
>
> I'm surprised the error message wasn't more useful in this case.
>
> > I can recompile PostgreSQL on the 64bit architecture without this
> configure option, but I wonder if there will be a performance drawback.
>
> It still won't work. If you want to replicate from a 64-bit machine to
> a 32-bit machine you will need to build a 32-bit version of PostgreSQL
> on the 64-bit machine.
>
> --
> Craig Ringer

Thank you for your answers.

I wasn't aware of the binary problem with replication.
Maybe the PostgreSQL docs should emphasize the architecture restriction.

I'll explore the other solutions.

--
Mathias



В списке pgsql-admin по дате отправления:

Предыдущее
От: Thomas Markus
Дата:
Сообщение: Re: Schema diagramming tool?
Следующее
От: Fujii Masao
Дата:
Сообщение: Re: PG 9.1 Looking for old WAL when promoting from recovery to master