Hi,
Am Donnerstag, den 14.03.2019, 15:26 +0100 schrieb Magnus Hagander:
> Given that the failure is data corruption, I don't think big fat
> warning is enough. We should really make it impossible to start up the
> postmaster by mistake during the checksum generation. People don't
> read the documentation until it's too late. And it might not even be
> under their control - some automated tool might go in and try to start
> postgres, and boom, corruption.
I guess you're right.
> One big-hammer method could be similar to what pg_upgrade does --
> temporarily rename away the controlfile so postgresql can't start, and
> when done, put it back.
That sounds like a good solution to me. I've made PoC patch for that,
see attached.
The only question is whether pg_checksums should try to move pg_control
back (i) on failure (ii) when interrupted?